Broadmore 1750 - Release 4.6

7-3

Configuration

Power-up

CAM\CONFIG\CURRENT – contains the complete set of startup configuration
data for all modules. This data is saved when Save Config. For PowerUp is
selected from the user interface.

CAM\CONFIG\DEFAULTS – contains the defaults to be used for new cards and
ports. Default values for new modules are automatically loaded if a startup
configuration for that module does not exist.

CAM\CONFIG\user-name – contains a snapshot of the system and module
configuration data as of the time the SAVE CONFIGURATION command was
issued. Data is stored in a subdirectory with user-supplied user name.

Power-up

1. Power-up the chassis. The Broadmore 1750 is designed for continuous service.

There is no on/off power switch since the system is designed to remain on at
all times. Simply apply power.

2. Observe the LED indicators to ensure that the system is operating properly. See

“Summary of Front Panel LEDs” on page

8-44

.

Power-on diagnostics take approximately 30 seconds, after which the LEDs
indicate the operational condition. Refer to Chapter 5, Maintenance and
Troubleshooting
if any problems arise. The rest of this chapter assumes normal
operation