Carrier Access Broadmore 1750 User Manual

Page 180

Advertising
background image

7-66

Broadmore 1750 - Release 4.6

Configuration

SVC Connection

Item

Definition

Connection Name

Press the space bar to select Connection Name and type a descriptive identifier (For
example, test port 2).

Local Slot

The Local Slot is the chassis slot.

Local Port Number

The Port number depends on the configuration.

Local Channel Map

The Channel map depends on the configuration. Channel map only applies to the
Structured DS3 SAMs. There is no channel mapping for the Unstructured DS3 and
Unstructured E3 SAMs, and this value will be displayed as N/A.

VP/VC (Transmit/
Receive)

The maximum settings for VP/VC are allocated using the Max VP/VC feature in
System Services (see

“Max VP/VC” on page

7-20

). Table 7-1 on page 7-20

shows the valid VP/VC values.

Destination ATM
Address

Enter the Destination ATM address. To view the ATM Address List, enter?.

Remote Slot

The Remote Slot is the chassis slot of the remote unit.

Remote Port Number
or Tributary

The Remote Port Number or Tributary depends on the configuration.

Remote Channel Map

The Remote Channel Map depends on the configuration.

CDV

Cell Delay Variation (CDV) is the difference between the expected arrival time and
the actual arrival time of the next cell. This value is expressed in number of cells.
The value can vary from 0 to 255. An initial value of 80 to 100 cells is
recommended.