Carrier Access Broadmore 1750 User Manual

Page 183

Advertising
background image

Broadmore 1750 - Release 4.6

7-69

Configuration

VP Reservation

Item

Comments

Connection Name

Press the space bar to select Connection Name and type a descriptive
identifier (For example, test port 2).

Local Slot

The Local Slot is the chassis slot.

VP

The range is 0 to one less than the value set for maximum VPs (see

“Max

VP/VC” on page

7-20

for valid values). If the Max VP/VC value is set to

2/65536, the VP number must be set to 0; a value of 1 is invalid.

NOTE: A maximum of 40 VPs can be defined for reservation.

VC Start

The default range is 32 to the value set for maximum VCs (see

“Max VP/

VC” on page

7-20

for valid values). VC numbers can start at 1 if the VP

is not set to 0.

VC End

The default range is 32 to the value set for maximum VCs (see

“Max VP/

VC” on page

7-20

for valid values). VC numbers can start at 1 if the VP

is not set to 0.