CPU IOM Replacement

9. Return the defective CPU card for repair. Contact Customer Service for an

RMA number and detailed procedures.

CPU IOM Replacement

There are no field-repairable items on the CPU IOM. This module does contain a
unique part of the Ethernet address such that the Broadmore 1750 system must be
alerted to the module change in order to restore service. Only replace the standby CPU
or CPU IOM on a redundant system. This will ensure correct programming of the IP,
CIP, LANE and ATM address information.

1. Ensure that you have a replacement CPU IOM with remote reboot jumpers set

correctly.

2. Follow the CAMMI sequence on the next page to signal CPU IOM removal.

3. Loosen top and bottom retaining screws, use ejectors to unseat the module, and

pull it straight out to remove.

4. Insert the replacement CPU IOM, ensuring alignment with the guides and

midplane connector. Tighten both retaining screws (finger tight only).

5. Return the defective CPU IOM for repair. Contact Customer Service for an

RMA number and detailed procedures.

Fan Replacement

There are no field-repairable items on the fan tray assembly. The air filters are
removable for routine cleaning. Removal and replacement of the fan assembly will not
impact normal Broadmore 1750 operations. This replacement should be completed
quickly to avoid possible overheating of Broadmore 1750 components. Follow the
steps below to replace the fan assembly.

1. Ensure that you have a replacement fan tray assembly.

2. Loosen retaining screws on both sides of the fan assembly to be replaced.

3. Remove the defective fan assembly from below the chassis by pulling it

straight out.

4. Insert the replacement fan assembly, ensuring alignment in the side guides.