Network interfaces, Sanitation procedures, Network interfaces -51 sanitation procedures -51 – Carrier Access Broadmore 1750 User Manual

Page 317

Advertising
background image

Broadmore 1750 - Release 4.6

11-51

Security Management (FIPS Mode)

Network Interfaces

Network Interfaces

Network Interface Modules (NIMs) are installed in the Broadmore ATM
Multiplexer and provide an interface to the ATM network. Each NIM contains
non-volatile Flash memory for storing run-time code. These chips are not
physically accessible from the ATM data path and thus cannot store data that
passes through the Broadmore.

Sanitation Procedures

The following table summarizes procedures for all Broadmore modules when
removing them from authorized areas to open areas.

Product Release

Product Type

Sanitation Procedure

Release 3.8
and earlier

Broadmore Unit

Power Off for 24 hours
Remove Disk-on-Chip from CPU

Network Interface
Modules

Power Off for 24 hours

CPU

Power Off for 24 hours
Remove Disk-on-Chip from CPU

Release 4.0
and later

Broadmore Unit

FIPS Zeroize Global/Standby
Power Off for 24 hours

Network Interface
Modules

Power Off for 24 hours

CPU

FIPS Zeroize Standby
Power Off for 24 hours