Broadmore 1750 - Release 4.6

Configuration

SAM Redundancy

Slot M has the highest priority, followed in order by slot J, slot F, and slot C. The P-
SAM provides redundancy according to the following:

Only a single W-SAM is protected

In the case of more than one request for the P-SAM, only the highest priority W-
SAM is protected

If the P-SAM is protecting a W-SAM, then a request from a lower priority W-
SAM is ignored until the higher priority clears

If the P-SAM is protecting a W-SAM, then a request from a higher priority W-
SAM is honored (and the protection for the first-protected W-SAM is lost)

P-SAM is invoked for removal of a W-SAM, or by user command

Redundancy is not reverting. After correction of a W-SAM problem, switch back
manually

Wait at least 15 seconds between removal and insertion of SAMs to ensure
system stabilization.