6-45

Missing acknowledgement

Behaviour of the flaps in the case of missing or unrequested
end position acknowledgements (single attempt).

The

OPEN or CLOSE output is activated once only, together

with the

ENBL output, if a “1” signal at the DirC or DirO input

is present, i.e. a fault is registered.
The

OPEN or CLOSE output is reset at the same time as the

ENBL output after the position monitoring time, which is set
via parameters.

If the control time monitoring has responded once, a new
control command

OPEN/CLOSE can be issued after a

RSET pulse.
If the control time has been exceeded and, subsequently,
a required acknowledgement issued, this must still be
reset before further control commands are handled.

Control time

The short signals at the inputs are spurious signals.
They are to be expected and will not trigger a fault.