712

Receiving failure or command overrun error. Call
Technical Support.

713

Receiving failure or illegal command. Call Technical
Support.

714

Receiving failure or undefined command. Call Technical
Support.

715

Invalid data length/data mismatch. The data in the
RFID Data Field has an incorrect data length or there is
a data type mismatch between selected data type and
actual data entered. The printer accepts either 8 bytes
(64-bit) or 12 bytes (96-bit) of data in the RFID Data
Field. See "Defining the RFID Data Field" for more
information on the data length and for selecting the
appropriate data type for the data being entered.
Make sure you did not send 96-bit data to a 64-bit RFID
tag. The printer does not recalibrate (feed a blank
label) after any RFID error.

730A memory allocation error occurred during initialization.

740

Command, hardware, inventory, or memory allocation
error. There may be an RFID hardware or memory
allocation error. The printer does not recalibrate (feed
a blank label) after any RFID error.

741

RFID tag missing. Tag not found in RF field. The RFID
tag was not found in the RF Field (area inside the
printer where RFID tag is programmed.) Check supply
loading. If you changed the supply or print position,
make sure the RFID tag was not moved out of the
programmable range. The printer does not recalibrate
(feed a blank label) after any RFID error. For more
information, refer to your RFID Quick Reference.

Diagnostics and Errors 8-21