Paxar Monarch 9850 User Manual

Page 98

Advertising
background image

X4. data_type

Data type. Options:

0

ASCII Hex - default (ASCII representation of Hex)

1

ASCII

2

ASCII Binary (ASCII representation of Binary)

3

Hex

Multiple data types are offered, which allows flexibility and
compatibility with your host system. You should know the
data type your host provides. If you are unsure, see the
examples on the following pages.

For example, the letter A has a decimal value of 65 in the
ASCII table. The hex (base 16) equivalent of decimal (base
10) is 41. Hex 41 in binary notation is 01000001.

Data Type

Character

MPCL Batch Data for a 96-bit RFID tag

ASCII Hex

41

"414141414141414141414141"

ASCII

A

"AAAAAAAAAAAA"

ASCII Binary

01000001

"010000010100000101000001010000010100000101000001
010000010100000101000001010000010100000101000001"

Hex

~065

"~065~065~065~065~065~065~065~065~065~065~065~065"

Example

X,5,24,0

p

Defines an RFID Data Field (field #5) with exactly 24 ASCII Hex
characters for a 96-bit RFID tag.

Sample Format

{F,1,A,R,E,600,400,"RDCI"

p

L,V,500,115,90,85,3

p

L,V,298,245,90,102,3

p

C,568,8,0,2,2,2,B,L,0,0,"FROM:",0

p

C,568,125,0,2,2,2,B,L,0,0,"CARRIER:",0

p

C,387,8,0,2,1,1,B,L,0,0,"(420) SHIP TO POSTAL CODE",0

p

C,391,250,0,2,1,1,B,L,0,0,"APPOINTMENT NUMBER:",0

p

C,327,250,0,2,1,1,B,L,0,0,"ITEM:",0

p

C,190,8,0,2,1,1,B,L,0,0,"UPC SHIPPING CONTAINER CODE",0

p

T,1,15,V,529,220,0,2,2,2,B,L,0,0,0

p

B,3,13,V,311,28,8,4,50,8,L,0

p

B,4,14,V,17,60,50,5,130,8,L,0

p

X,5,24,0

p

T,6,20,V,415,270,0,50,15,15,B,L,0,2

p

R,4,5,1,16,1,0

p

.
.
.}

RFID Field

Copy Option from field 5
(RFID Field) to field 6
(Text Field)

3-32 Defining Fields

Advertising