INDICATORS

INDICATORS

INDICATORS

INDICATORS

INDICATORS

°C

Lit when process variable is in Celsius degree.

°F

Lit when process variable is in Fahrenheit degree.

ST

Flashing when the first step of SMART algorithm is
activated.
Lit when the second step of SMART algorithm is activated.

%

Lit when the lower display shows the output power value.

MAN Lit when device is in manual mode.
REM Lit when device is controlled by serial link.
RSP Lit when Remote Set point is used.
SPX Lit when an auxiliary Set point (SP2, SP3 or Sp4) is used.

Flashing when a temporary set point, from serial link, is
used.

1

Lit when OUT 1 is used as control output and it is in ON
condition or when Event 1 is at logic level 1 or when alarm
1 is in alarm state and acknowledged.
Flashes when alarm 1 is in alarm state and it is not
acknowledged.

2

Lit when OUT 2 is used as control output and it is in ON
condition or when Event 2 is at logic level 1 or when alarm
2 is in alarm state and acknowledged.
Flashes when alarm 2 is in alarm state and it is not
acknowledged.

3

Lit when OUT 3 is used as control output and it is in ON
condition or when servomotor output increases or when

Event 3 is at logic level 1 or when alarm 3 is in alarm state
and acknowledged.
Flashes when alarm 3 is in alarm state and it is not
acknowledged.

4

Lit when OUT 4 is used as control output and it is in ON
condition or when servomotor output decreases or when
Event 4 is at logic level 1 or when alarm 4 is in alarm state
and acknowledged.
Flashes when alarm 4 is in alarm state and it is not
acknowledged.

IN 1 to IN 4 Lit when the related digital input is in ON condition.
OUT 10 to OUT 19 Lit when the related digital output is in ON

condition.