Specifying the lsa arrival interval, Specifying the lsa generation interval – H3C Technologies H3C S10500 Series Switches User Manual

Page 105

Advertising
background image

90

NOTE:

When network changes are not frequent, the

minimum-interval is adopted. If network changes become

frequent, the SPF calculation interval is incremented by

incremental-interval × 2

n-2

(n is the number of

calculation times) each time a calculation occurs until the

maximum-interval is reached.

Specifying the LSA arrival interval

After receiving the same LSA as the previously received LSA within the LSA arrival interval, OSPF discards

the LSA.
Follow these steps to configure the LSA arrival interval:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter OSPF view

ospf [ process-id | router-id router-id |
vpn-instance vpn-instance-name ] *

Configure the LSA arrival interval

lsa-arrival-interval interval

Optional
1000 milliseconds by
default

NOTE:

The interval set with the lsa-arrival-interval command must be smaller than or equal to the interval set with
the lsa-generation-interval command.

Specifying the LSA generation interval

You can adjust the LSA generation interval to protect network resources and routers from being over

consumed by frequent network changes.
Follow these steps to configure the LSA generation interval:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter OSPF view

ospf [ process-id | router-id router-id |
vpn-instance vpn-instance-name ] *

Required

Configure the LSA
generation interval

lsa-generation-interval
maximum-interval [ initial-interval

[ incremental-interval ] ]

Optional
By default, the maximum interval is 5

seconds, the minimum interval is 0

milliseconds, and the incremental
interval is 5000 milliseconds.

NOTE:

When network changes are not frequent, LSAs are generated at the

minimum-interval. If network changes

become frequent, the LSA generation interval is incremented by

incremental-interval × 2

n-2

(n is the

number of generation times) each time a LSA generation occurs until the

maximum-interval is reached.

Advertising