H3C Technologies H3C S10500 Series Switches User Manual

Page 146

Advertising
background image

131

Routing Table : Public

Summary Count : 2

Destination: 120.1.1.0/24

Protocol: OSPF Process ID: 0

Preference: 0 Cost: 2

IpPrecedence: QosLcId:

NextHop: 192.168.0.100 Interface: Vlan-interface10

BkNextHop: 0.0.0.0 BkInterface:

RelyNextHop: 0.0.0.0 Neighbor : 0.0.0.0

Tunnel ID: 0x0 Label: NULL

BKTunnel ID: 0x0 BKLabel: NULL

State: Active Adv Age: 00h58m10s

Tag: 0

Destination: 120.1.1.0/24

Protocol: OSPF Process ID: 1

Preference: 10 Cost: 4

IpPrecedence: QosLcId:

NextHop: 10.1.1.100 Interface: Vlan-interface11

BkNextHop: 0.0.0.0 BkInterface:

RelyNextHop: 0.0.0.0 Neighbor : 0.0.0.0

Tunnel ID: 0x0 Label: NULL

BKTunnel ID: 0x0 BKLabel: NULL

State: Invalid Adv Age: 00h58m05s

Tag: 0

# Enable BFD debugging on Switch A.

<SwitchA> debugging bfd scm

<SwitchA> debugging bfd event

<SwitchA> debugging ospf event

<SwitchA> terminal debugging

# After the link over which Switch A and Switch B communicates through the Layer 2 switch fails, Switch

A can quickly detect the changes on Switch B.

%Nov 12 18:34:48:823 2005 SwitchA BFD/5/LOG: Sess[10.1.0.102/10.1.0.100, vlan10], Sta :

UP->DOWN, Diag: 1

%Nov 12 18:34:48:824 2005 SwitchA RM/4/RMLOG:OSPF-NBRCHANGE: Process 1, Neighbour

10.1.0.102 (vlan10) from Full to Down

*0.50673825 SwitchA BFD/8/SCM:Sess[10.1.0.102/10.1.0.100, vlan10],Oper: Reset

*0.50673825 SwitchA BFD/8/EVENT:Send sess-down Msg, [Src:10.1.0.102, Dst:10.1.0.100,

vlan10] Protocol: OSPF

*0.50673826 SwitchA RM/7/RMDEBUG:OSPF-BFD: Message Type rcv BFD down, Connect Type

direct-connect, Src IP Address 10.1.0.102, Src IFIndex 5, Dst IP Address 10.1.0.100

*0.50673827 SwitchA RM/7/RMDEBUG:OSPF-BFD: Message Type delete session, Connect Type

direct-connect, Src IP Address 10.1.0.102, Src IFIndex 5, Dst IP Address 10.1.0.100

OSPF 1: Nbr 10.1.0.100 Rcv KillNbr State Full -> Down.

*0.50673829 SwitchA BFD/8/EVENT:Receive Delete-sess, [Src:10.1.0.102, Dst:10.1.0.100,

vlan10], Direct, Proto:OSPF

*0.50673830 SwitchA BFD/8/SCM:Sess[10.1.0.102/10.1.0.100, vlan10], Oper: Del

application(OSPF)