[SwitchB-Vlan-interface100] quit

[SwitchB] interface vlan-interface 200

[SwitchB-Vlan-interface200] ospfv3 1 area 1

[SwitchB-Vlan-interface200] quit

# Configure Switch C.

<SwitchC> system-view

[SwitchC] ipv6

[SwitchC] ospfv3

[SwitchC-ospfv3-1] router-id 3.3.3.3

[SwitchC-ospfv3-1] quit

[SwitchC] interface vlan-interface 100

[SwitchC-Vlan-interface100] ospfv3 1 area 0

[SwitchC-Vlan-interface100] quit

[SwitchC] interface vlan-interface 400

[SwitchC-Vlan-interface400] ospfv3 1 area 2

[SwitchC-Vlan-interface400] quit

# Configure Switch D.

<SwitchD> system-view

[SwitchD] ipv6

[SwitchD] ospfv3

[SwitchD-ospfv3-1] router-id 4.4.4.4

[SwitchD-ospfv3-1] quit

[SwitchD] interface Vlan-interface 400

[SwitchD-Vlan-interface400] ospfv3 1 area 2

[SwitchD-Vlan-interface400] quit

# Display OSPFv3 neighbor information on Switch B.

[SwitchB] display ospfv3 peer

OSPFv3 Area ID 0.0.0.0 (Process 1)

----------------------------------------------------------------------

Neighbor ID Pri State Dead Time Interface Instance ID

3.3.3.3 1 Full/DR 00:00:39 Vlan100 0

OSPFv3 Area ID 0.0.0.1 (Process 1)

----------------------------------------------------------------------

Neighbor ID Pri State Dead Time Interface Instance ID

1.1.1.1 1 Full/Backup 00:00:38 Vlan200 0

# Display OSPFv3 neighbor information on Switch C.

[SwitchC] display ospfv3 peer

OSPFv3 Area ID 0.0.0.0 (Process 1)

----------------------------------------------------------------------

Neighbor ID Pri State Dead Time Interface Instance ID

2.2.2.2 1 Full/Backup 00:00:39 Vlan100 0

OSPFv3 Area ID 0.0.0.2 (Process 1)

----------------------------------------------------------------------

Neighbor ID Pri State Dead Time Interface Instance ID

Advertising