H3C Technologies H3C S10500 Series Switches User Manual

Page 334

Advertising
background image

319

[SwitchA-Vlan-interface10] isis ipv6 enable 1

[SwitchA-Vlan-interface10] quit

[SwitchA] interface vlan-interface 11

[SwitchA-Vlan-interface11] isis ipv6 enable 1

[SwitchA-Vlan-interface11] quit

# Configure Switch B.

<SwitchB> system-view

[SwitchB] ipv6

[SwitchB] isis 1

[SwitchB-isis-1] is-level level-1

[SwitchB-isis-1] network-entity 10.0000.0000.0002.00

[SwitchB-isis-1] ipv6 enable

[SwitchB-isis-1] quit

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] isis ipv6 enable 1

[SwitchB-Vlan-interface10] quit

[SwitchB] interface vlan-interface 13

[SwitchB-Vlan-interface13] isis ipv6 enable 1

[SwitchB-Vlan-interface13] quit

# Configure Switch C.

<SwitchC> system-view

[SwitchC] ipv6

[SwitchC] isis 1

[SwitchC-isis-1] network-entity 10.0000.0000.0003.00

[SwitchC-isis-1] ipv6 enable

[SwitchC-isis-1] quit

[SwitchC] interface vlan-interface 11

[SwitchC-Vlan-interface11] isis ipv6 enable 1

[SwitchC-Vlan-interface11] quit

[SwitchC] interface vlan-interface 13

[SwitchC-Vlan-interface13] isis ipv6 enable 1

[SwitchC-Vlan-interface13] quit

3.

Configure BFD functions.

# Enable BFD on Switch A and configure BFD parameters.

[SwitchA] bfd session init-mode active

[SwitchA] interface vlan-interface 10

[SwitchA-Vlan-interface10] isis ipv6 bfd enable

[SwitchA-Vlan-interface10] bfd min-transmit-interval 500

[SwitchA-Vlan-interface10] bfd min-receive-interval 500

[SwitchA-Vlan-interface10] bfd detect-multiplier 7

[SwitchA-Vlan-interface10] return

# Enable BFD on Switch B and configure BFD parameters.

[SwitchB] bfd session init-mode active

[SwitchB] interface vlan-interface 10

[SwitchB-Vlan-interface10] isis ipv6 bfd enable

[SwitchB-Vlan-interface10] bfd min-transmit-interval 500

[SwitchB-Vlan-interface10] bfd min-receive-interval 500

Advertising