H3C Technologies H3C S10500 Series Switches User Manual

Page 363

Advertising
background image

348

5.

Configure BFD parameters (you can use default BFD parameters instead).

# Configure Switch A.

[SwitchA] bfd session init-mode active

[SwitchA] interface vlan-interface 100

Configure the minimum interval for transmitting BFD control packets as 500 milliseconds.

[SwitchA-Vlan-interface100] bfd min-transmit-interval 500

Configure the minimum interval for receiving BFD control packets as 500 milliseconds.

[SwitchA-Vlan-interface100] bfd min-receive-interval 500

Configure the detect multiplier as 7.

[SwitchA-Vlan-interface100] bfd detect-multiplier 7

[SwitchA-Vlan-interface100] quit

# Configure Switch C.

[SwitchC] bfd session init-mode active

[SwitchC] interface vlan-interface 101

Configure the minimum interval for transmitting BFD control packets as 500 milliseconds.

[SwitchC-Vlan-interface101] bfd min-transmit-interval 500

Configure the minimum interval for receiving BFD control packets as 500 milliseconds.

[SwitchC-Vlan-interface101] bfd min-receive-interval 500

Configure the detect multiplier as 7.

[SwitchC-Vlan-interface101] bfd detect-multiplier 7

[SwitchC-Vlan-interface101] return

6.

Verify the configuration.

The following operations are made on Switch C. Operations on Switch A and Switch B are similar and
are not shown.
# Display detailed BFD session information.

<SwitchC> display bfd session verbose

Total session number: 1 Up session number: 1 Init mode: Active

IPv6 Session working under Ctrl mode:

Local Discr: 17 Remote Discr: 13

Source IP: 3001::3

Destination IP: 3000::1

Session State: Up Interface: Vlan-interface101

Min Trans Inter: 500ms Act Trans Inter: 500ms

Min Recv Inter: 500ms Act Detect Inter: 3000ms

Recv Pkt Num: 57 Send Pkt Num: 53

Hold Time: 2200ms Connect Type: Direct

Running Up for: 00:00:06 Auth mode: none

Protocol: BGP6

Diag Info: No Diagnostic

The output shows that a BFD session is established between Switch A’s VLAN-interface 100 and Switch
C’s VLAN-interface 101 and that BFD runs properly.