1.9.4 Swap Code

N

O

C

HANGE

, W

ORD

S

WAP

, W

ORD AND

B

YTE

S

WAP

, B

YTE

S

WAP

You may need to swap the order of the bytes in the registers during the copy

process in order to change the alignment of bytes between dissimilar protocols.

This parameter is helpful when dealing with floating-point or other multi-register

values, as there is no standard method of storage of these data types in slave

devices.
The following table defines the values and their associated operations:

Swap Code

Description

No Swap

No change is made in the byte ordering (1234 = 1234)

Word Swap

The words are swapped (1234=3412)

Word and

Byte Swap

The words are swapped, then the bytes in each word are swapped (1234=4321)

Bytes

The bytes in each word are swapped (1234=2143)