Last Global Command
The value of the last global command code received from the master.

Bit

Designation

Significance

0

Reserved

1

Clear_Data

With this command the ASCI output data is deleted in data transfer

buffer and is changed to next transfer data buffer contents.

2

Unfreeze

With "Unfreeze": freezing input data is cancelled.

3

Freeze

The ASCI input data is fetched from next transfer buffer to data
transfer buffer and frozen. New input data is not fetched again until

the master sends the next "Freeze" command.

4

Unsync

The "Unsync" command cancels the "Sync" command.

5

Sync

The ASCI output data transferred with a WRITE_READ_DATA
telegram is changed from data transfer buffer next state buffer. The

following transferred output data is kept in data transfer buffer until

the next "Sync" command is given.

6,7

Reserved

The Reserved designation specifies that these bits are reserved for

future function expansions.