Minolta Magicolor 3100 Series User Manual

Page 102

Advertising
background image

2-102

2.3.3 Executing/stopping the diagnosis

[Executing diagnosis]

Click the ”DIAG ON' button, and the TEST PRINT, EEPROM, Diagnostics Input Test, and Diagnostics
Output Test buttons on the initial screen become active to start various diagnostic functions.

[Stopping diagnosis]

Click the “DIAG OFF” button, and the current diagnosis is stopped and the TEST PRINT, EEPROM,
Diagnostics Input Test, and Diagnostics Output Test buttons on the initial screen become inactive.

2.3.4 Kinds of diagnostic functions

Four kinds of diagnostic functions are provided.

2.3.5 Communication log files

The Hanabi Service Commander can record the data (commands and statuses) transmitted/received
between the PC and the PWBA HNB MCU in a file. The following files are automatically created in the
folder where the Hanabi Service Commander has been installed.

log0.txt
log1.txt
log2.txt
log3.txt

The data of one day are written to one file even if the Diagnostic Commander is started/exited repeatedly.
Up to four files (namely, files for four days) are created. The data of the fifth day will overwrite the oldest file.

2.3.6 Exiting Diagnostic Commander

Click the Close button.

Functions

Description

Test Print

Executes a test print of the pattern stored in the printer.

Input Test

Checks the sensors and switches and there condition.

Output Test

Operate the motors and solenoids.

EEPROM Read/Write

Read/write various data in EEPROM (Non-Volatile
Memory).

Advertising