Fip-dc – Minolta Magicolor 3100 Series User Manual

Page 93

Advertising
background image

Chapter 1 Troubleshooting

1-93

FIP-DC

Step

Check

Yes

No

1

Initial check
Check the following for damage.

Blown fuse in LVPS STD
AC power supply failure

Repair

Go to step [2]

2

Checking LVPS STD
Disconnect the connectors J163, J165 and J164 from the
LVPS STD, and turn the AC SW on.
Is P163-1PIN <=> P163-2PIN +24VDC?

Go to step [3]

Replace LVPS
STD

3

Checking LVPS STD
Is P165-1PIN <=> P165-2PIN +5VDC?

Go to step [4]

Replace LVPS
STD

4

Checking LVPS STD
Is P165-3PIN <=> P165-4PIN +3.3VDC?

Go to step [5]

Replace LVPS
STD

5

Checking HARNESS ASSY LV RPG
Turn the AC SW off, and connect J164 to the LVPS STD,
then turn the AC SW on.
Is P/J164-1PIN <=> P/J164-2PIN +3.3VDC?

Go to step [6]

Check HARNESS
ASSY LV RPG for
frame short

6

Checking HARNESS ASSY LVNC
Turn the AC SW off, and connect J165 to the LVPS STD,
then turn the AC SW on.
Is P/J165-1PIN <=> P/J165-2PIN +5VDC?

Go to step [7]

Check HARNESS
ASSY LVNC for
frame short

7

Checking HARNESS ASSY 24V
Turn the AC SW off, and connect J163 to the LVPS STD,
then turn the AC SW on.
Is P/J163-1PIN <=> P/J163-2PIN +24VDC?

End of work

Check HARNESS
ASSY 24V for
frame short

Advertising