15

Check FAN FUSER
Does FAN FUSER function normally?
Using FAN FUSER diagnostic tool, check by Diagnostic
Output Test.

Replace PWBA
HNB MCU

Go to step [16]

16

Check PWBA HNB DRV for signal
Print 1 sheet.
Is P/J50-7PIN <=> P/J50-9PIN +24VDC?

Go to step [19]

Go to step [17]

17

Check PWBA HNB DRV for signal
Print 1 sheet.
Is P/J42-30PIN <=> P/J42-14PIN 0VDC?

Go to step [18]

Replace PWBA
HNB DRV

18

Check PWBA HNB MCU for signal
Print 1 sheet.
Is P/J12-1PIN <=> P/J12-17PIN 0VDC?

Replace PWBA
HNB MCU

Replace
HARNESS ASSY
DRV2

19

Check HARNESS ASSY DUP for continuity
J50 <=> J137 check continuous?

Go to step [20]

Replace
HARNESS ASSY
DUP

20

Check FAN FUSER
Check if an error occurs though the FAN FUSER was
replaced with a new one.

Go to step [21]

End of work

21

Check PWBA HNB DRV for signal
Print 1 sheet.
Is P/J50-8PIN <=> P/J50-9PIN +3.3VDC?

Replace FAN
FUSER

Go to step [22]

22

Check PWBA HNB DRV for signal
Print 1 sheet.
Is P/J42-27PIN <=> P/J42-14PIN +3.3VDC?

Replace PWBA
HNB DRV

Go to step [23]

23

Check PWBA HNB MCU for signal
Print 1 sheet.
Is P/J12-4PIN <=> P/J12-17PIN +3.3VDC?

Replace
HARNESS ASSY
DRV2

Replace PWBA
HNB MCU

Step

Check

Yes

No

Advertising