Chapter 1 Troubleshooting

1-83

FIP-P2 Blank Prints

Condition / initial check

∆The entire image area is blank.

▼ Initial check ▼

Incorrect parts, improper installation, damage, deformation, dirt, foreign substance attached, etc.
∇ Major parts to be checked ∇

Imaging Unit (PHD), Transfer Unit (BTR), ROS ASSY, PWBA HNB MCU

Item

Check

Remedy

1

Intercepted laser beam path
Check if foreign substance or dirt is present in the laser
beam path between ROS ASSY and Drum in PHD
ASSY

Remove foreign substance or dirt

2

Faulty ROS ASSY
Is the image quality improved if ROS ASSY is replaced?

Replace the ROS ASSY

3

Faulty charging or developing
Is the image quality improved if PHD ASSY is replaced?

Replace the PHD ASSY

4

Faulty transfer
Is the image quality improved if BTR ASSY is replaced?

Replace the BTR ASSY

5

Faulty PWBA HNB MCU
Is the image quality improved if PWBA HNB MCU is
replaced?

Replace the PWBA HNB MCU