Rrp9.5 actuator regi (pl9.1.9), Rrp9.5 actuator regi (pl9.1.9) -231 – Minolta Magicolor 3100 Series User Manual

Page 231

Advertising
background image

Chapter 3 Removal and Replacement Procedures

3-229

RRP9.5

ACTUATOR REGI (PL9.1.9)

Figure: ACTUATOR REGI Removal

Removal

1) Remove the CHUTE ASSY REGI. (RRP9.3)
2) Holding the shielding portion of the ACTUATOR REGI from the CHUTE ASSY REGI (PL9.1.6), move

the ACTUATOR REGI leftward and extract the right shaft of the ACTUATOR REGI from the bearing of
the CHUTE ASSY REGI.

3) Pull out the ACTUATOR REGI from the CHUTE ASSY REGI together with the SPRING SENSOR

REGI (PL9.1.10).

4) Remove the SPRING SENSOR REGI from the ACTUATOR REGI.

Replacement
Replace the components in the reverse order of removal.