Chapter 1 Troubleshooting

1-41

FIP-5 PHD Detached (Imaging Unit Missing)

Step

Check

Yes

No

1

Initial check
Check the following for damage.

Imaging Unit (PHD) condition
PWBA CRUM in Imaging Unit (PHD) condition

Replace the parts
concerned

Go to step [2]

2

Check PWBA CRUM
Is PWBA CRUM connector connected to the
harness connector normally?

Go to step [3]

Replace
HARNESS ASSY
CRUM

3

Check HARNESS ASSY CRUM for continuity
J170 <=> J71 check continuous?

Go to step [4]

Replace
HARNESS ASSY
CRUM

4

Check HARNESS ASSY EEPROM for continuity
J17 <=> J140 check continuous?

Go to step [5]

Replace
HARNESS ASSY
EEPROM

5

Check Imaging Unit (PHD)
Replace Imaging Unit (PHD), and check if an error occurs

Replace PWBA
HNB MCU

End of work