Fip-28 btr life over (replace transfer unit) – Minolta Magicolor 3100 Series User Manual

Page 68

Advertising
background image

1-68

FIP-28 BTR Life Over (Replace Transfer Unit)

Step

Check

Yes

No

1

Initial check
Check the following for damage.

Transfer Unit (BTR) condition
SENSOR TONER FULL condition

Replace the parts
concerned

With tool
Go to step [2]
Without tool
Go to step [3]

2

Check SENSOR TONER FULL
Does SENSOR TONER FULL function normally?
Using SENSOR TONER FULL diagnostic tool, check by
Diagnostic Input Test.

Go to step [6]

Go to step [3]

3

Check HARNESS ASSY TFLSNS for signal
Remove the Transfer Unit (BTR)
Is P/J141-2PIN <=> P/J141-1PIN 0VDC?

Go to step [6]

Go to step [4]

4

Check HARNESS ASSY TFLSNS for signal
Is P/J141-3PIN <=> P/J141-1PIN +5VDC?

Go to step [5]

Replace
HARNESS ASSY
EEPROM

5

Check HARNESS ASSY TFLSNS for continuity
J142 <=> J142 check continuous?

Replace SENSOR
TONER FULL

Replace
HARNESS ASSY
TFLSNS

6

Check Transfer Unit (BTR)
Replace new Transfer Unit (BTR), and check if an error
occurs

Replace PWBA
HNB MCU

End of work