Chapter 3 Removal and Replacement Procedures

3-195

RRP6.2

SENSOR PHOTO:FULL STACK (PL6.1.4)

Figure: SENSOR PHOTO:FULL STACK Removal

Removal

1) Remove the COVER ASSY FRONT HEAD. (RRP1.2)
2) Remove the ACTUATOR FULL. (RRP6.3)
3) Release the hooks at 3 positions securing the SENSOR PHOTO: FULL STACK to the CHUTE ASSY

OUT.

4) Remove the connector (P/J134) on the SENSOR PHOTO: FULL STACK from top portion of the

CHUTE ASSY OUT (PL6.1.1) of the printer.

5) Remove the SENSOR PHOTO:FULL STACK from the CHUTE ASSY OUT.

Replacement
Replace the components in the reverse order of removal.