3 parts requiring periodical replacement, Operating environment, 1 installation temperature / humidity – Minolta Magicolor 3100 Series User Manual

Page 414: 2 installation altitude, 3 installation horizontality, 4 ambient lighting, Safety / environment conditions, 1 safety standard, 2 laser safety standard, 3 emi

Advertising
background image

8-414

◆ Magenta toner cartridge:equivalent to about 6,000 prints
◆ Cyan toner cartridge:equivalent to about 6,000 prints
◆ Fuser unit:equivalent to about 100,000 prints

5.3 Parts Requiring Periodical Replacement

Following parts are replaced when a certain number of sheets are printed (life over) to prevent troubles.

◆ FUSE ASSY:Equivalent to about 100.000 prints
◆ RETARD ROLL:Equivalent to about 100,000 prints

6. Operating Environment

6.1 Installation Temperature / Humidity

Operated at: 5 to 32°C(41 to 90°F) / 15 to 85% RH

6.2 Installation

Altitude

0 to 3,100m(10,170ft)

6.3 Installation

Horizontality

Before and after the installation surface:within 5mm in 646mm
Right and left of installation surface:within 10mm in 560mm

6.4 Ambient

Lighting

3000 Lux or less (without no direct sun beams)

7. Safety / Environment Conditions

7.1 Safety

Standard

◆ 100V / 120V system

UL1950 3rd Edition
CSA C22.2 No.950-M95

◆ 220V / 240V system

IEC60950 2nd Edition

7.2 Laser Safety Standard

◆ 100V / 120V system

FDA21CFR Chapter 1, Subchapter J, Section 1010, 1040

◆ 220V / 240V system

IEC60825 Class 1 Laser Product

7.3 EMI

◆ 100V system

Advertising