Minolta Magicolor 3100 Series User Manual

Page 114

Advertising
background image

2-114

2.7.6 Write Life / Adjustment Data

After the PWBA HNB MCU was replaced, the NVM data read from the PWB before replacement and saved
in the text file are written to the new PWB. For this purpose, the text file created in 2.7.5 “Save Life /
Adjustment Data" is used (.NSD extension).

1) Click the “Write Life / Adjustment Data” button, and the following screen will appear.

2) Enter the file name of the text file created in "2.7.5 Save Life / Adjustment Data" where the NVM data

to be written are saved in the [File Name] field.

3) Click the “Open” button.
4) Upon completion of writing, the message is displayed.

Successful termination: complete!
Unsuccessful termination: Write - in operation of a nonvolatile memory was not completed normally.