Fip-36 full stack (output bin full) – Minolta Magicolor 3100 Series User Manual

Page 76

Advertising
background image

1-76

FIP-36 Full Stack (Output Bin Full)

Step

Check

Yes

No

1

Initial check
Check the following for damage.

SENSOR FULL STACK condition
Actuator condition

Replace the parts
concerned

With tool
Go to step [2]
Without tool
Go to step [3]

2

Check SENSOR FULL STACK
Does SENSOR FULL STACK function normally?
Using SENSOR FULL STACK diagnostic tool, check by
Diagnostic Input Test.

Replace PWBA
HNB MCU

Go to step [3]

3

Check HARNESS ASSY FRONT2 for signal
Is P/J139-6PIN <=> P/J139-5PIN +3.3VDC?

Replace PWBA
HNB MCU

Go to step [4]

4

Check HARNESS ASSY FRONT2 for signal
Is P/J139-4PIN <=> P/J139-5PIN +3.3VDC?

Replace SENSOR
FULL STACK

Replace
HARNESS ASSY
FRONT1A
Replace PWBA
HNB MCU

Advertising