Minolta Magicolor 3100 Series User Manual

Page 229

Advertising
background image

Chapter 3 Removal and Replacement Procedures

3-227

Removal

1) Release the latch at A from the printer and open the FRONT ASSY IN (PL5.1.1).
1) Remove the PHD.
2) Release the hooks at 2 positions securing the HOUSING ASSY ELEC (PL9.1.11) to the printer and

remove the HOUSING ASSY ELEC upward.

3) Remove the connector (P/J18) of the CHUTE ASSY REGI from the printer.

Remove the connector (P/J32) of the OHP SENSOR, if installed.

4) Remove 4 screws securing the CHUTE ASSY REGI to the printer.
5) Raise the left end of the CHUTE ASSY REGI and pull out the CHUTE ASSY REGI leftward from the

printer.

Replacement
Replace the components in the reverse order of removal.