Chapter 1 Troubleshooting

1-67

FIP-27 PHD Life Over (Replace Imaging Unit)

Step

Check

Yes

No

1

Initial check
Check the following for damage.

Imaging Unit (PHD) condition
PWBA CRUM in Imaging Unit (PHD) condition

Replace the parts
concerned

Go to step [2]

2

Check PWBA CRUM for connection
Is PWBA CRUM connector connected to the harness
connector normally?

Go to step [3]

Replace
HARNESS ASSY
CRUM

3

Check HARNESS ASSY CRUM for continuity
J170 <=> J71check continuous?

Go to step [4]

Replace
HARNESS ASSY
CRUM

4

Check HARNESS ASSY EEPROM for continuity
P71 <=> J140 check continuous?

Go to step [5]

Replace
HARNESS ASSY
EEPROM

5

Check Imaging Unit (PHD)
Replace new Imaging Unit (PHD), and check if an error
occurs.

Replace PWBA
HNB MCU

End of work