Chapter 7 Wiring Diagrams and Signal Information

7-379

LVPS overcurrent protection circuit

This circuit stops all outputs, if the power supply voltage 24VDC, 5VDC, or 3.3VDC is shorted.
The circuit is reset, when after the cause of short was removed, the power is turned off, and then on
again after certain time.

LVPS overvoltage protection circuit

This circuit stops all outputs, if the power supply voltage 24VDC, 5VDC, or 3.3VDC exceeds the
specified voltage respectively.
At this time, the operating point is 32VDC or less for 24VDC, 7VDC or less for 5VDC, or 6V or less
for 3.3VDC.
The circuit is reset, when the power is turned off, and then on again after certain time.

FAN output circuit

For the FAN REAR ON (H) signal, the output voltage varies depending on the status of FAN LOW
signal and FAN STOP signal.

Output stop by Interlock Switch

Turning off the Interlock Switch mounted on the PWBA HNB DRV causes the "I/L +24VDC" circuit to
be shut off. Consequently, +24VDC supply to the PWBA HNB MCU and to the parts connected to the
PWBA HNB DRV is stopped.

Signal line name

Description

FAN LOW

FAN REAR drive control signals

FAN STOP
FAN REAR FAIL(H)+3.3VDC

FAN REAR fail detection signal (High: Fail, Low: Normal)

FAN REAR ON(H)

FAN REAR ON/OFF control signal

FAN LOW

FAN STOP

FAN REAR ON(H)

High

High

24V

Low

High

15V

High

Low

0V

Low

Low

0V