Rrp3.17 link actuator (pl3.3.5), Rrp3.17 link actuator (pl3.3.5) -173 – Minolta Magicolor 3100 Series User Manual

Page 173

Advertising
background image

Chapter 3 Removal and Replacement Procedures

3-171

RRP3.17 LINK ACTUATOR (PL3.3.5)

Figure: LINK ACTUATOR Removal

Removal

1) Pull out the CASSETTE from the printer.
2) Shift the bracket of the LINK ACTUATOR from the shaft of the ACTUATOR NO PAPER (PL3.3.5) of

the printer.

3) Extract the actuator of the LINK ACTUATOR from the hole on the printer and remove the LINK ACTU-

ATOR.

Replacement
Replace the components in the reverse order of removal.

Advertising