8. Sensors

102

PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer

Bindicator(s)

Assemble bindicator(s) according to instruction sheet packed with them.

NOTE: See

Figure 8B on Page 98

for placement of bindicator(s).

1. Lower Bindicator, RA4

Measure inner (not outer) diameter of gasket. This is the diameter of hole needed to mount lower
bindicator on wall sheet.

Locate wall sheet directly below access port. Center hole vertically on that wall sheet. Cut a hole in
wall sheet that measures the same as gasket inner diameter.

Install assembled lower bindicator into hole cut in wall sheet, fitting gasket tight against wall sheet.

Bolt with 5/16" x 3/4" whiz lock bolts and 5/16" nuts.

2. Upper Bindicator, RA6

If required (for conveyor or slide gate fill dryers only), install upper bindicator on dryer roof.

Figure 8J Center hole vertically for

bindicator (arrows).

Figure 8K Installing upper bindicator.

Figure 8L Upper bindicator (A) and lower

bindicator (B) installed.

Figure 8M View inside dryer - Lower bindicator.

B