18. Windows and Doors

200

PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer

Heat Section Door (Continued)

Screw two (2) door latches in pre-drilled holes on outside of heat section door.

Screw two (2) hooking brackets to door frame. Position to keep heat section door tightly shut.

Check fit of heat section door in door frame, and adjust as required.

Figure 18AQ Close Up - Installing heat section

door sleeve.

Figure 18AR Tap hammering heat section door sleeve

around inside of door frame.

Figure 18AS Pressing bulb seal around inside edge

of heat section door sleeve.