6. Tower Roof

PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer

77

Install roof rungs and expansion ring clips to tower roof sheets during tower roof sheet installation.

Count bolt holes (BH) from bottom of rib of tower roof sheet.

Set of four (4) roof rungs - install across tower roof sheet with cut out for access port in BH1,
BH3, BH4 and BH5.

Remaining roof rungs - install across every other tower roof sheet in BH5.

Install expansion ring clips in every BH3.

Figure 6U Bolt holes (BH) for tower roof

rungs and expansion ring clips.

Figure 6V

Figure 6W Expansion Ring Clip (4")

Figure 6X Close Up - Roof rungs installed

to ribs of tower roof sheets.

BH1

BH3

BH4

BH5

Ref #

Length

Part

Qty

A

41-1/4"

Tower Roof Rung

1

B

36"

Tower Roof Rung

1

C

29"

Tower Roof Rung

1

D

22"

Tower Roof Rung

9

E

15"

Tower Roof Rung

1