15. Fans, Divider Hopper, Reducer Walkway

PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer

171

Divider Hopper

Divider hopper is formed by joining inner divider hopper sections and outer divider hopper sections in a
“V” shape.

Divider hopper encircles fan cluster.

Divider hopper divides heat section from cool section.

Divider hopper fits between fan skirting and inner wall of dryer.

For divider hopper placement in the dryer model, see

Figure 15C on Page 156

to

Figure 15F on Page 159

.

Keep “V” of divider hopper level.

1. Snug bolt top tabs (closely spaced) on inner divider hopper sections to bottom of blower skirting.

(See Figure 15AW.)

Snug bolt inner divider hopper sections together.

Use 5/16" x 3/4" galvanized bolts and nuts.

Figure 15AW Inner Divider Hopper Section

Figure 15AX Outer Divider Hopper Section

Figure 15AY Bolting top tabs of inner divider hopper to

bottom of fan skirting.

Bottom tabs are widely spaced.

Top tabs are closely space.

Bottom tabs are widely spaced.

Top tabs are closely space.