19. Tower Base

PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer

209

Compression Angle Weldments

See Figure 19A on Page 204 and

Figure 19B on Page 205

for placement of compression angle weldments.

From outside dryer, bolt compression angle weldment to sealing strip.

(See Figure 19L,

Figure 19M and

Figure 19N on Page 210.)

Use 5/16" x 1" bolts, nuts, and washers.

Figure 19K Compression Angle Weldment

Figure 19L Bolting compression angle weldments to

bottom of sealing strip.

Figure 19M Close Up - Bolting compression angle weldments

to sealing strip. Trim sealing strip if required.

Top

Compression angle weldment

Base stiffener weldment

Sealing strip

Compression angle weldment

Solid sheet