Grease tubes, Chapter 17 grease tubes – Grain Systems PNEG-707GSI User Manual

Page 184

Advertising
background image

184

PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer

17. Grease Tubes

See Orientation Section on Page 19

for dryer dimensions, components, wall sheet guidelines, etc.

See Appendix A on Page 435

for tools and equipment,

Appendix B on Page 437

for hardware, etc.

NOTE: Upper bearing on fan requires grease tube for access.

NOTE: Lower bearing on fan requires no grease tube.

All required fittings are shipped attached to grease tube.

1. Unscrew grease zerk from fan.

2. Install grease zerk to coupling on beam clamp end of grease tube.

3. Install elbow end of grease tube to fan.

4. Clamp beam clamp to bottom edge of fan, or where convenient.

Figure 17A Close Up - Grease zerk on fan.

Figure 17B Grease tube for upper bearing on fan.

Figure 17C Close Up - Elbow end of grease tube (A).

Figure 17D Close Up - Beam clamp end of grease

tube (B).

Important Safety Precautions:
Dryer has sharp edges. These sharp edges may cause serious injury. Use
appropriate personal protective equipment. Use proper lifting techniques.

A

B

A. Elbow end
B. Beam clamp end

A

B

Advertising