9. Lift Dryer

PNEG-707 12', 18', 24' and 30' GSI Commercial Tower Dryer

111

6. Lower dryer.

Check to be sure bottom of vertical channel is on outside of jig clip.

Figure 9F Positioning jack next to dryer.

Figure 9G Checking jack is 11-1/2" to 12" from dryer.

7. At top, loosely bolt vertical channel splices to vertical channel already on dryer. At bottom, loose

bolt vertical channels to jig clip to align dryer.

8. As each lift of dryer is constructed, install wall sheets, ladders, catwalks, platforms, and other dryer

features as required.

(See Orientation Section on Page 19.)

Figure 9H Checking jack is plumb and level.

Figure 9I Jacks in place around dryer.