Feet (continued)
Mounting polyamide feet
XEFG
Polyamide feet are used with 64 mm structural beams
only.
Mounting:
Adjusting mounts and vibration absorbers
XLFS 20 P, XLFJ 69
Mounting:
Allen key
5 mm
Hex socket head screws (included)
MC6S 8×16
1
Mount the foot onto the beam end by sliding the foot
compression clamps into the beam T-slot.
2
Tighten the screws. The recommended tightening
torque is 15 Nm.
1
Adjusting mounts are screwed onto the bottom of the
foot and fastened with the locking nuts that are
included.
2
Vibration absorbers are snapped on to the bottom of
the adjusting mounts.