Drip trays and drip catchers (continued) – FlexLink XS (45 мм) Монтаж User Manual
Page 48

48
Assembly
Drip trays and drip catchers (continued)
Mounting drip trays
X_DT
Connect drip trays to each other using connecting strips
(XLCJ 5
×140) and set screws. Use silicone caulk to seal
joints.
Mounting:
Box wrench
13 mm
T-bolts
XLAT 17
Nuts
XLAN 8
Washers
BRB 8,4×16
Square nuts
XLAQ 8
Screws
M6S 8×16
Connecting strips
XLCJ 5×76
Drip tray bracket
XLDB 21×100
1
Use T-bolts, nuts and washers to attach the drip tray
brackets to the conveyor beam T-slot.
2
Insert the required number of square nuts in the drip
tray T-slot. Attach the drip tray to the drip tray brack-
ets. Do not tighten the screws fully.
Attach pans and end cap to the drip tray by inserting
square nuts into the slots on the drip tray. Tighten the
screws using a wrench.
3
Adjust the position of the drip tray. Tighten all screws.
4
If Type A or B beam support brackets with screw slots
are being used, drip tray brackets may not be needed.
The drip trays can then be attached directly on to the
beam support brackets if they are wide enough.