Drip trays and drip catchers (continued) – FlexLink XS (45 мм) Монтаж User Manual
Page 49

Assembly
49
Drip trays and drip catchers (continued)
Drip pans, end pans, end caps
Drip pan for horizontal bend X..DH
End pan X..DE
End cap X..DC
End pan for idler end unit X..DD
Drip tray connector X..DJ
In addition to regular drip trays, you will need drip pans,
end pans and/or end caps. Drip pans are used in bends,
and end pans and caps are used at the ends of the drip
tray. The pans are equipped with threaded outlets so that
waste fluid can be drained into waste reservoirs.
Mounting:
Box wrench
13 mm
Square nuts
Screws
M6S 8×16
Washers
BRB 8,4×16
1
Attach square nuts to one end of the drip pan and
tighten them loosely. (Use one pair with X_DC, X_DD
and X_DE; two pairs with X_DJ and X_DH.) Slide the
drip pan on to a drip tray section.
2
Slide the next drip tray section (if required), with the
square nuts attached, on to the drip pan.
3
Insert screws and brackets and tighten them loosely.
4
Adjust the position of the drip tray and tighten the
screws.