Assembly

Drive units

Introduction

Step three is to mount drive and idler units to the frame
structure. All drive and idler units come with connecting
strips included. Attach them to the conveyor beam using
an Allen key and the set screws that are included.

Drive units can be attached to supports of various

kinds; check your drawing to see how your conveyor is
designed.

It should be remembered that conveyor chains should

always be pulled, not pushed, by the drive unit.

Mounting of end drive unit

X..EB 5 H

Caution:

When installing a drive unit, ensure that
the slip clutch is fully released.

The conveyor chain catenary of
end drive units must be main-
tained during the system lifetime.
When the conveyor chain is visi-
ble through the slot in the side-
plate, it must be shortened.

Mounting:

Allen key

4 mm

1

Mount the end drive unit on to the end of the con-
veyor:

Release the four set screws that are inserted into the
drive unit connecting strips. Insert the connecting
strips into the T-slot of the beam you want attached to
the end drive unit.

Make sure that the set screws do not prevent the con-
necting strips from sliding into place.

2

Tighten the set screws using an Allen key.