Supplementary Manual CANopen for NORDAC SK 20E

10

Subject to technical amendments

BU 0260 GB

1.1 Overview

Features of the CANopen Modules

Electrically isolated bus interface

Data transfer rate from 10kbit/sec to 1 Mbit/sec

Easy connection, optionally via M12 round plugs or screw terminals

Integrated bus terminating resistor (switchable)

 CAN bus-specific status indication with 2 LEDs on the internal (Customer Unit) and external

(Technology Unit) technology option

 DEVICE or FI-specific status indication with 2 LEDs on the internal (Customer Unit) and external

(Technology Unit) technology option

CAN interface as per specifications 2.0A and 2.0B

Up to four 24V inputs and two 24V outputs are integrated into the bus module

Direct connection of up to 4 sensors and 2 activators via M12 round plug connectors on the SK TU4-
CAO-M12(-C) version. Visualisation of signal status via LEDs

Transmission and selection of process and parameter data

 CAN Bus gateway solution → up to 4 frequency inverters can be connected to a CANopen bus

module. Each FI is allocated its own SDO channel

Up to 63 nodes (e.g. CANopen bus modules) on a single bus. With this, up to 252 frequency inverters
can be operated on a single bus by means of gateway.

Support of 11 bit and 29 bit identifiers by the technology modules

 Supports DS-301 communications profile and DS-402 drive profile for “Velocity Mode” (with

Technology Units)

Programming of all frequency inverter parameters using SDO

Dynamic PDO mapping (5 TxPDOs and 5 RxPDOs) for great reduction in the number of parameters

Heartbeat and node-guarding monitoring functionality

Interface (RS232/RS485) for parameter access by means of the SK PAR-3H manual control unit or
NORDCON software via RJ12 connector (Except for SK CU4-CAO. Here parameter access via the
SK 200E frequency inverter is possible)

Integrated EEPROM with extensive bus-specific parameter database with parameter editing facilities via:
- ParameterBox and Nordcon: direct access / direct saving
- CANopen Bus Saving via - Index 0x1010 sub0 Store Parameters,

- Index 0x1011 sub0 Restore default Parameters

Available as versions for installation in the inverter (IP20) or in a separate housing (optionally IP55 / IP66)


1.2 Delivery

Check the equipment immediately after delivery/unpacking for transport damage such as deformation or
loose parts.
If there is any damage, contact the carrier immediately and implement a thorough assessment.

Important! This also applies even if the packaging is undamaged.