4.9.5

Error codes – cancellation of parameter communication

The following table gives an overview of the possible error codes which may be generated on cancellation of
parameter communication.

Error code

Description

0x0503 0000

Toggle bit unchanged

0x0504 0000

SDO timeout message

0x0504 0001

Client/Server command invalid / unknown

0x0504 0005

No memory

0x0601 0000

Illegal access to an object

0x0601 0001

Access to write-only parameter

0x0601 0002

Access to read-only object

0x0602 0000

Object does not exist in object dictionary

0x0604 0041

Object cannot be mapped in PDO

0x0604 0042

Object exceeds PDO length

0x0604 0043

Parameter incompatibility

0x0604 0047

Module internally incompatible

0x0606 0000

Access failure due to hardware error

0x0607 0010

Data type or parameter length do not match

0x0607 0012

Data type incorrect, parameter length too long

0x0607 0013

Data type incorrect, parameter length too short

0x0609 0011

Sub-Index of parameter does not exist

0x0609 0030

Parameter value range overflow

0x0609 0031

Parameter value range overflow

0x0609 0032

Parameter value range undershot

0x0800 0020

Data transfer or storage not possible

0x0800 0021

Data transfer or storage not possible; reason: local control


4.9.6

Error messages (EMCY message)

The following error groups are defined in the communication profile DS-301.

Error Code (hex)

Significance

00xx No

error

10xx

Undefined error type

20xx Current

error

30xx Voltage

error

40xx Temperature

error

50xx Hardware

error

60xx Software

error

70xx Additional

module

80xx Communication
90xx External

error

FF00

Specific to device