Supplementary Manual CANopen for NORDAC SK 20E

42

Subject to technical amendments

BU 0260 GB

STW

SW1

SW2

SW3

DOs

4.5.2.6 PDO transmission / access in USS Protocol Mode

The internal status machine of the frequency inverter (USS) applies for the transfer of process data. Access to
the individual frequency inverters is according to the following pattern (see Section 4.9.4 "Frequency inverter
objects (2000hex - 3005hex )").


In the following example of a VIPA control, the linking of the objects (control word and setpoint) of FI 1 to those
of the CANopen master is illustrated.

4th frequency inverter

Setpoint

- PDO in USS Protocol Mode

Sequence in CAN telegram
Indication in word

Index

Sub-index Description

0 0x3000

4

Control

word

(STW)

1

0x3002 10

Setpoint 1 (SW1)

2

0x3002 11

Setpoint 2 (SW2)

3

0x3002 12

Setpoint 3 (SW3)

3rd frequency inverter

Setpoint

- PDO in USS Protocol Mode

Sequence in CAN telegram
Indication in word

Index

Sub-index Description

0 0x3000

3

Control

word

(STW)

1

0x3002 7

Setpoint 1 (SW1)

2

0x3002 8

Setpoint 2 (SW2)

3

0x3002 9

Setpoint 3 (SW3)

2nd frequency inverter

Setpoint

- PDO in USS Protocol Mode

Sequence in CAN telegram
Indication in word

Index

Sub-index Description

0 0x3000

2

Control

word

(STW)

1

0x3002 4

Setpoint 1 (SW1)

2

0x3002 5

Setpoint 2 (SW2)

3

0x3002 6

Setpoint 3 (SW3)

1st frequency inverter

Setpoint

- PDO in USS Protocol Mode

Sequence in CAN telegram
Indication in word

Index

Sub-index Description

0 0x3000

1

Control

word

(STW)

1

0x3002 1

Setpoint 1 (SW1)

2

0x3002 2

Setpoint 2 (SW2)

3

0x3002 3

Setpoint 3 (SW3)

PDO setpoint

Gateway

mode