NORD Drivesystems BU0260 User Manual

Page 57

Advertising
background image

4 Commissioning

BU 0260 GB

Subject to technical amendments

57

The allocation of special error codes for Nord inverters is carried out as follows:

Error code

FI error number (corresponds to (P700))

Explanation

0x1000 ---

The error number transmitted by FI is not known to
the technology unit. It must be read out via (P700)
or an actual value.

0x4210

1.0 / 1.1

Meaning:

see frequency inverter manual.

0x4310

2.0 / 2.1 / 2.2

0x2310 3.0
0x7112 3.1
0x2311 3.2
0x2312 3.3
0x2200

4.0 / 4.1

0x3210 5.0
0x3110 5.1
0x3230 6.0
0x3120 6.1
0x3130 7.0
0x6310 8.0
0x5530

8.1 / 8.2

0x8100

10.0 / 10.1 / 10.2

0x8111

10.3 / 10.4 / 10.5 / 10.6 / 10.7 / 10.9

0x5000 10.8
0x5110 11.0
0x9000 12.0
0x7305 13.0
0x8400 13.1
0x8300 13.2
0x7120

16.0 / 16.1

0x5300 17.0
0x7120 18.0
0x7120 19.0
0x5510 20.0
0x6000

20.1 / 20.2 / 20.3 / 20.4 / 20.5 / 20.6 / 20.7

0x5520 20.8
0x6000

20.9 / 21.0 / 21.1 / 21.2 / 21.3

0x8110

---

CAN reception overflow (message lost)

0x8111

---

CAN reception overflow (message lost)

0x8120

---

Passive CAN error

0x8130

---

CAN Guarding / Heartbeat error detected

0x8210

---

PDO length error

0x8220

---

PDO length error (too long)