6 Error monitoring and error messages

BU 0260 GB

Subject to technical amendments

77

General process data monitoring...

Detailed monitoring of subscribers

… of a

technology

unit (TB)

… of a

frequency

inverter (FI)

Option

monitoring

Node / Life Guarding

Heartbeat

relevant
parameters

(P151) (P513) (P120)

(P166

[-01]) x (P167)

(P166[-02])

relate to...

... basic bus communication ...

Bus nodes

Bus node

... of the TO

... of the FI

... to the TB

Monitoring by

TB

FI

FI

Bus nodes

Bus master

Example

{ 500 ms}

If no further
telegram is
recieved within
500ms after
receipt of a
telegram, an
error is
triggered.

{ 0.5 s }

If no further
telegram is
recieved within
0.5s after receipt
of a telegram, an
error is triggered.

{ 1 }

If the
communication
to a module is
interupted, or
the module
cannot be found
on switch-on, an
error message is
triggered.

{ 250 }x{ 3 }

If the subscriber does not
receive the expected
response within 250ms
of sending a data
package (telegram) or it
does not receive a
further data package
within 750ms (250 ms x
3) of receiving a data
package, an error is
triggered.

{ 250 }

The slave sends a
corresponding telegram
every 250 ms, which can
be processed by an
overriding control
system.

Error code

E010 / E10.3

E010 / E10.2

E010 / E10.8

or E10.9

E010 / E10.2

/

General process data monitoring with a technology unit (SK xU4-…)

The parameter (P152) "Timeout external bus" generally monitors the existence of bus communication. If no
process data is received within the parameterised monitoring time (The content of the process data is
irrelevant) the subscriber assumes that the bus communication to this subscriber is generally faulty and reports
an error.


General monitoring of frequency inverter process data

SK 500E series frequency inverters offer the facility for monitoring the active bus interface by means of the
parameter (P513) "Telegram timeout". If the frequency inverter does not receive a telegram within the time
entered here, it assumes that there is a general fault with the bus communication and reports an error.

Note: With SK 200E series frequency inverters, this function of this parameter is implemented by parameter
(P120). All settings (except { -0.1 }) are then without effect in parameter (P153).

Start

Order

Master

Slave

Response

Order

Response

Time
in ms

Node Guarding
max. (P166)

Life Guarding
max.
(P166) x (P167)

Comparison of Node Guarding / Life Guarding