NORD Drivesystems BU0260 User Manual

Page 26

Advertising
background image

Supplementary Manual CANopen for NORDAC SK 20E

26

Subject to technical amendments

BU 0260 GB

Terminal/
Designation

Function

Data

Description / wiring suggestion

Parameter

23 24V

24

External 24V supply

As for terminal 11

-

25 DIN2

Digital input 2
[I/O CANopen DIN2]

Low 0V ... 5V
High 15V ... 30V
R

i

= 8.1k

Input capacitance 10nF
Scan rate 1 ms

Each digital input has a reaction
time of 1ms.
Inputs as per
EN 61131-2

Type 1

P174

26 DIN4

Digital input 4
[I/O CANopen DIN4]

P174

27 GND

28

Reference potential
for digital signals

External supply voltage for system
bus and digital inputs (DIN1 to
DIN4)

-

29 24V

30

External 24V supply

As for terminal 11

-

Potential isolation

31 24V

o

External 24V supply
for the DOs

24VDC -/+20%
Up to 1A, according to
load
reverse polarity protected

External supply voltage for digital
outputs (DO1 and DO2)
If necessary, bridge to

24V

terminal

-

32 GND

o

Reference potential
for digital signals

External supply voltage for digital
outputs (DO1 and DO2)
If necessary, bridge to

GND

terminal

-

33 DO1

Digital output 1
[I/O CANopen DO1]

Low = 0V
High: 24V
Rated current: 500mA
each

The digital outputs should be used
with a separate 24V supply

P150
P175

34 DO2

Digital output 2
[I/O CANopen DO2]

P150
P175

35 GND

o


36

Reference potential
for digital signals

External supply voltage for digital
outputs (DO1 and DO2)
If necessary, bridge to

GND

terminal

-


Details of the M12 connections of the SK
TU4-CAO-M12
The special wiring of the M12 round plug connector
enables the connection of both single and double
sensors, which are equipped with normal M12
system connectors in the standard sensor/actuator
configuration.
With the use of M12 round plug connectors, the
terminal bar connectors for the digital inputs
(Terminals 19, 20, 25, 26) must not be used.


Illustration of wiring of M12
connector to SK TU4-...-M12

Advertising