NORD Drivesystems BU0260 User Manual

Page 60

Advertising
background image

Supplementary Manual CANopen for NORDAC SK 20E

60

Subject to technical amendments

BU 0260 GB

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

P481

...

[-01]

...

...

[-10]

Function Bus I/O Out bits

0 ... 39

{ all 0 }

The bus I/O Out bits are perceived as multi-function relay outputs. They can be set to the same
functions (P434).

These I/O bits can also be used in combination with the AS Interface (SK 225E or SK 235E) or
the I/O extension (SK CU4-IOE or SK TU4-IOE).

… [-01] = Bus I/O Out Bit 0

… [-02] = Bus I/O Out Bit 1

… [-03] = Bus I/O Out Bit 2

… [-04] = Bus I/O Out Bit 3

… [-05] = Bus I/O Out Bit 4

… [-06] = Bus I/O Out Bit 5

… [-07] =Flag 1

… [-08] = Flag 2

… [-09] = Bit 10 BUS status word

… [-10] = Bit 13 BUS status word

The possible functions for the bus Out bits can be found in the table of functions for the relay
(P434)

P482

...

[-01]

...

...

[-08]

Standardisation of bus I/O Out bits

-400 … 400 %

{ all 100 }

Adjustment of the limit values of the bus Out bits. For a negative value, the output function will
be output negative.

Once the limit value is reached and positive values are delivered, the output produces a High
signal, for negative setting values a Low signal.

P483

...

[-01]

...

...

[-08]

Hysteresis of bus I/O Out bits

S

1 … 100 %

{ all 10 }

Difference between switch-on and switch-off point to prevent oscillation of the output signal.


Advertising